Mitsubishi Electric offers a dual-jack, single-stage, hole-less design for both passenger and service elevators. This design assures the user reliable operation for up to two stops and 16 feet of travel. Additional travel may be achieved with customized application.

Introducing our PureRide® Vertical Transportation Solutions

PureRide® Touchless Control

This simple, no-touch product allows users to call an elevator and designate a destination floor by placing a hand or finger over a sensor without the need to touch at all.

Elevator Call System via Smartphone

Our exclusive smartphone application is designed to offer even more convenient access to elevators equipped with the DOAS Integrated with Security System. This intuitive and user-friendly app increases mobility and helps add value to the building. With the ID Card Call function, passengers can request an elevator from the lobby to their destination floor before entering building security. After authenticating at security via ID card, passengers confirm their assigned elevator once inside the building. With the Smartphone Call function, passengers already in the building can select their departure and destination floors when requesting an elevator. With both functions, the smartphone displays the elevator assigned to the passenger, shows its current status, and uses push notifications to alert the passenger as the elevator car approaches. Passengers can also easily request a wheelchair accessible elevator, when needed.

Holeless Passenger IDH-S and IDH-M

Opening Front Opening Front & Rear Front Opening Front & Rear Front Opening
Capacity (lbs.) 2100/Passenger 2100/Passenger 2500/Passenger 2500/Passenger 3000/Passenger
Speed (fpm) 100, 125, 150 100, 125, 150 100, 125, 150 100, 125, 150 100, 125, 150
Hoistway (w x d) 7’ 6” x 5’ 10” 7’ 6” x 6’ 7 ¼” 8’ 6” x 5’ 10” 8’ 6” x 6’ 7 ¼” 8’ 6” x 6’ 3”
Platform (w x d) 6’ x 5’ 1” 6’ x 5’ 7” 7’ x 5’ 1” 7’ x 5’ 7” 7’ x 5’ 6”
Inside Clear 5’ 8” x 4’ 3 ¾” 5’ 8” x 4’ 3 ½” 6’ 8” x 4’ 3 ¾” 6’ 8” x 4’ 3 ½” 6’ 8” x 4’ 8 ¾”
Door Type SS SS SS, CO SS, CO SS, CO
Entrance Width 3’ 3’ 3’ 6” 3’ 6” 3’ 6”
Pit 4’ 4’ 4’ 4’ 4’
Overhead* 12’ 6” 12’ 6” 12’ 6” 12’ 6” 12’ 6”
Maximum Travel* 12’ 0" 12’ 0" 12’ 0" 12’ 0" 12’ 0"
Maximum Number of Stops 2 2 2 2 2
Opening Front & Rear Front Opening Front & Rear Front Opening Front & Rear
Capacity (lbs.) 3000/Passenger 3500/Passenger 3500/Passenger 4000/Passenger 4000/Passenger
Speed (fpm) 100, 125, 150 100, 125, 150 100, 125, 150 100, 125, 150 100, 125, 150
Hoistway (w x d) 8’ 6” x 7’ 0 ¼” 8’ 6” x 6’ 11” 8’ 6” x 7’ 8 ¼” 9’ 8” x 6’ 11” 9’ 8” x 7’ 8 ¼”
Platform (w x d) 7’ x 6’ 7’ x 6’ 2” 7’ x 6’ 8” 8’ x 6’ 2” 8’ x 6’ 8”
Inside Clear 6’ 8” x 4’ 8 ½” 6’ 8” x 5’ 4 ¾” 6’ 8” x 5’ 4 ½” 7’ 8” x 5’ 4 ¾” 7’ 8” x 5’ 4 ½”
Door Type SS, CO SS, CO SS, CO CO CO
Entrance Width 3’ 6” 3’ 6” 3’ 6” 4’ 4’
Pit 4’ 4’ 4’ 4’ 4’
Overhead* 12’ 6” 12’ 6” 12’ 6” 12’ 6” 12’ 6”
Maximum Travel* 12’ 0” 12’ 0” 12’ 0” 12’ 0” 12’ 0”
Maximum Number of Stops 2 2 2 2 2

*Note: The contents of these tables are standard specifications based on an 8 ft. cab height with 4’-0” pit and 12’-0” travel or less. Please reference “holeless single stage overhead dimensions” for other arrangement or consult your local sales office for specifications.

Holeless Passenger Duty Tables

Holeless Service IDH-H

Opening Front Opening Front & Rear Front Opening Front and Rear
Capacity (lbs.) 4000/Service 4000/Service 4500/Service 4500/Service
Speed (fpm) 100, 125, 150 100, 125, 150 100, 125, 150 100, 125, 150
Hoistway (w x d) 7’ 8” x 9’ 1” 7’ 8” x 10’ 1 ¾” 7’ 8” x 9’ 8” 7’ 8” x 10’ 7 ¾”
Platform (w x d) 6’ x 8’ 3” 6’ x 8’ 10 ¾” 6’ x 8’ 10” 6’ x 9’ 4 ¾”
Inside Clear 5’ 8” x 7’ 3 ¾” 5’ 8” x 7’ 4 ¼” 5’ 8” x 7’ 10 ¾” 5’ 8” x 7’ 10 ¼”
Door Type 2S 2S 2S 2S
Entrance Width 4’ 4’ 4’ 4’
Pit 4’ 4’ 4’ 4’
Overhead* 12’ 10” 12’ 10” 12’ 10” 12’ 10”
Maximum Travel* 12’ 0” 12’ 0” 12’ 0” 12’ 0”
Maximum Number of Stops 2 2 2 2
Opening Front Opening Front & Rear Front Opening Front and Rear
Capacity (lbs.) 5000/Service 5000/Service 5000/Service 5000/Service
Speed (fpm) 100, 125, 150 100, 125, 150 100, 125, 150 100, 125, 150
Hoistway (w x d) 7’ 8” x 10’ 3” 7’ 8” x 11’ 2 ¾” 8’ 5” x 10’ 3” 8’ 5” x 11’ 2 ¾”
Platform (w x d) 6’ x 9’ 5” 6’ x 9’ 11 ¾” 6’ 4” x 9’ 5” 6’ 4” x 9’ 11 ¾”
Inside Clear 5’ 8” x 8’ 5 ¾” 5’ 8” x 8’ 5 ¼” 6’ x 8’ 5 ¾” 6’ x 8’ 5 ¼”
Door Type 2S 2S 2S 2S
Entrance Width 4’ 4’ 4’ 6” 4’ 6”
Pit 4’ 4’ 4’ 4’
Overhead* 12’ 10” 12’ 10” 12’ 10” 12’ 10”
Maximum Travel* 12’ 0” 12’ 0” 12’ 0” 12’ 0”
Maximum Number of Stops 2 2 2 2

*Note: The contents of these tables are standard specifications based on an 8 ft. cab height with 4’-0” pit and 12’-0” travel or less. Please reference “holeless single stage overhead dimensions” for other arrangement or consult your local sales office for specifications.

Holeless Service Duty Tables

Passenger - One Car

  • SS = Single Side Opening
  • CO = Center Opening
Capacity (lbs.) / Speed (fpm) Front Door Type Front / Rear Door Type
2100/100/125/150

SS [PDF] [DWG]

SS [PDF] [DWG]

2500/100/125/150

SS [PDF] [DWG]

CO [PDF]

SS [PDF] [DWG]

CO [PDF]

3000/100/125/150

SS [PDF] [DWG]

CO [PDF] [DWG]

SS [PDF] [DWG]

CO [PDF] [DWG]

3500/100/125/150

SS [PDF] [DWG]

CO [PDF] [DWG]

SS [PDF] [DWG]

CO [PDF] [DWG]

4000/100/125/150

CO [PDF] [DWG]

CO [PDF] [DWG]

Service - One Car

  • 2S = Two Speed Side Opening
Capacity (lbs.) / Speed (fpm) Front Door Type Front / Rear Door Type
4000/100/125/150

2S [PDF] [DWG]

2S [PDF] [DWG]

4500/100/125/150

2S [PDF] [DWG]

2S [PDF] [DWG]

5000/100/125/150

2S [PDF] [DWG] (4-0 Door)

2S [PDF] [DWG] (4-6 Door)

2S [PDF] [DWG] (4-0 Door)

2S [PDF] [DWG] (4-6 Door)